Gas Chromatography

Varian GC’s (4)

  • Flame Ionization Detectors (FID’s)
    • sensitive to volatile organic compounds
  • Thermionic Specific Detector (TSD)
    • sensitive to volatile organic phosphorous and nitrogen compounds
  • Electron Capture Detectors (ECD)
    • sensitive to volatile halogenated organic compounds
  • Flame Photometric Detector (FPD)
    • sensitive to volatile sulfur and phosphorus organic compounds
  • Autosamplers with capacities up to 48 samples
  • Packed and capillary column capabilities

Agilent GC’s (13)

  • Flame Ionization Detectors (FID’s)
    • sensitive to volatile organic compounds
  • Micro Electron Capture Detectors (MECD)
    • Extremely sensitive to halogenated organic compounds
  • Thermal Conductivity Detector (TCD)
    • sensitive to volatile organic compounds
  • Capillary column capabilities
  • Accessories
    • CDS Pyroprobe with autosampler
    • CDS Purge and Trap Unit
    • Varian Genesis Headspace Analyzer with Autosampler
    • Asist Headspace Analyzer with Autosampler
    • Leap Autosamplers – capacity 105 samples (8)
    • Optic 2 on column large volume thermal desorbtions
    • Entech 7032-L SUMMA canister auto sampler (2)
      • Capable of running 2 batches of 21 cans simultaneously

Gas Chromatography/Mass Spectrometry (GC/MSD)

Agilent Systems (6)

  • HP-5972 (1) Mass Selective Detector
  • HP-5973 (2) Mass Selective Detector
  • HP-5973N (1) Mass Selective Detector
  • HP5975 (2) Mass Selective Detector
  • Sample Introduction onto the column by: gas sampling valve, pyrolysis probe, direct injection, headspace autosampler, thermal desorbtion
  • One unit also has a FID
  • HP5975 has both EI & CI capabilities

HIGH PERFORMANCE Liquid Chromatography (HPLC)

  • HP-1100
    • Quatrannary Gradient Pump
    • Vacuum Degasser
    • Heated Column and Mobile Phase Oven
    • Diode Array Detector
    • 91 Position Auto Sampler
    • ChemStation Controlled
  • HP-1100
    • Quatrannary Gradient Pump
    • Vacuum Degasser
    • Variable Wavelength UV Detector
    • 91 Position Auto Sampler
  • HP-1100
    • Quatrannary Gradient Pump
    • Vacuum Degasser
    • Waters 490 Variable Wavelength UV Detector
    • Heated Column and Mobile Phase Oven
    • Waters 410 Differential Refractometer
  • Hitachi :
    • L-7100 Quatrannary Gradient Pump
    • L-7250 121 Position Auto Sampler
    • ESA Coul Array 4 Channel Detector.
  • Agilent HP-1040
    • Quatrannary Gradient Pump
    • 30 Position Auto Sampler
    • Wyatt Dawn HELEOS II (18 angle) Multi-Angle (MALS) Light Scattering
    • Wyatt Viscostar (Viscosity)
    • Wyatt Optilab rEX Refractive Index Detector
    • ChemStation & Astra Control.

Ion Chromatography

Dionex DX500

  • PAD Detector
  • Conductivity Detector
  • Capable of Gradient Operation
  • Autosampler

Supercritical Fluid Chromatography/Extraction (SFC/SFE)

  • ISCO system for capillary column SFC and SFE
  • Berger Scientific for packed column SFC

Environmental Testing And Analysis Equipment

  • Custom Equipped Mobile Laboratory
    • On site analysis using specialized equipment such as GC/MS, GC/ECD/SUMMA Cannister Analysis and thermal desorption GC/MS
  • HOODSTACK® emissions testing
  • Total organic carbon analyzers
  • Method 21 compliance testing
  • Data loggers
  • Heated umbilical sampling lines
  • CO, CO2, and O2 analyzers
  • Pressure and differential pressure instruments

Please click on link for information about particular lab.

 

Contact | Services| Capabilities | Laboratory | Clients Only

Laboratory | Labs & Instruments | Virtual Tour

©2007 Ashland
® Registered Trademark, Ashland Inc.
Privacy Notice -- Terms of Use

*Responsible Care and Responsible Care logo are Registered service marks of the American Chemistry Council in the U.S. and of other entities in other countries.

Site development by 1 Firm, Inc.