SEPARATIONS & ENVIRONMENTAL ANALYSIS
Gas Chromatography
Varian GC’s (4)
- Flame Ionization Detectors (FID’s)
- sensitive to volatile organic compounds
- Thermionic Specific Detector (TSD)
- sensitive to volatile organic phosphorous and nitrogen compounds
- Electron Capture Detectors (ECD)
- sensitive to volatile halogenated organic compounds
- Flame Photometric Detector (FPD)
- sensitive to volatile sulfur and phosphorus organic compounds
- Autosamplers with capacities up to 48 samples
- Packed and capillary column capabilities
Agilent GC’s (13)
- Flame Ionization Detectors (FID’s)
- sensitive to volatile organic compounds
- Micro Electron Capture Detectors (MECD)
- Extremely sensitive to halogenated organic compounds
- Thermal Conductivity Detector (TCD)
- sensitive to volatile organic compounds
- Capillary column capabilities
- Accessories
- CDS Pyroprobe with autosampler
- CDS Purge and Trap Unit
- Varian Genesis Headspace Analyzer with Autosampler
- Asist Headspace Analyzer with Autosampler
- Leap Autosamplers – capacity 105 samples (8)
- Optic 2 on column large volume thermal desorbtions
- Entech 7032-L SUMMA canister auto sampler (2)
- Capable of running 2 batches of 21 cans simultaneously
Gas Chromatography/Mass Spectrometry (GC/MSD)
Agilent Systems (6)
- HP-5972 (1) Mass Selective Detector
- HP-5973 (2) Mass Selective Detector
- HP-5973N (1) Mass Selective Detector
- HP5975 (2) Mass Selective Detector
- Sample Introduction onto the column by: gas sampling valve, pyrolysis probe, direct injection, headspace autosampler, thermal desorbtion
- One unit also has a FID
- HP5975 has both EI & CI capabilities
HIGH PERFORMANCE Liquid Chromatography (HPLC)
- HP-1100
- Quatrannary Gradient Pump
- Vacuum Degasser
- Heated Column and Mobile Phase Oven
- Diode Array Detector
- 91 Position Auto Sampler
- ChemStation Controlled
- HP-1100
- Quatrannary Gradient Pump
- Vacuum Degasser
- Variable Wavelength UV Detector
- 91 Position Auto Sampler
- HP-1100
- Quatrannary Gradient Pump
- Vacuum Degasser
- Waters 490 Variable Wavelength UV Detector
- Heated Column and Mobile Phase Oven
- Waters 410 Differential Refractometer
- Hitachi :
- L-7100 Quatrannary Gradient Pump
- L-7250 121 Position Auto Sampler
- ESA Coul Array 4 Channel Detector.
- Agilent HP-1040
- Quatrannary Gradient Pump
- 30 Position Auto Sampler
- Wyatt Dawn HELEOS II (18 angle) Multi-Angle (MALS) Light Scattering
- Wyatt Viscostar (Viscosity)
- Wyatt Optilab rEX Refractive Index Detector
- ChemStation & Astra Control.
Ion Chromatography
Dionex DX500
- PAD Detector
- Conductivity Detector
- Capable of Gradient Operation
- Autosampler
Supercritical Fluid Chromatography/Extraction (SFC/SFE)
- ISCO system for capillary column SFC and SFE
- Berger Scientific for packed column SFC
Environmental Testing And Analysis Equipment
- Custom Equipped Mobile Laboratory
- On site analysis using specialized equipment such as GC/MS, GC/ECD/SUMMA Cannister Analysis and thermal desorption GC/MS
- HOODSTACK® emissions testing
- Total organic carbon analyzers
- Method 21 compliance testing
- Data loggers
- Heated umbilical sampling lines
- CO, CO2, and O2 analyzers
- Pressure and differential pressure instruments
|
|
Please click on link for information about
particular lab.
|
|
|
Contact
| Services| Capabilities
| Laboratory | Clients
Only
Laboratory
| Labs & Instruments | Virtual Tour
©2007 Ashland
® Registered Trademark, Ashland Inc.
Privacy Notice -- Terms of Use
*Responsible
Care and Responsible Care logo are Registered service marks of the American
Chemistry Council in the U.S. and of other entities in other countries.
Site
development by 1 Firm, Inc.
|
 |