SPECTROSCOPY AND MICROSCOPY
FOURIER TRANSFORM INFRARED SPECTROSCOPY
Varian / BIO-RAD FTS-175
Varian FTS7000
- Research grade instrument equipped with KBr optics for mid-IR region 4000- 400 cm-1
- Detector: DTGS
- UMA 600 IR Microscope for transmission or reflectance analysis
- MCT detector
- Focal Plane Array Imaging Detector
- Germanium attenuated total reflectance (ATR) mapping objective
- motorized mapping stage
Sample Handling Accessories
- MTEC photoacoustic cell
- diamond anvil and compression cells
- diffuse and specular reflectance accessories
- attenuated total reflectance (ATR): horizontal, vertical, variable angle, and micro
- sealed liquid cell
Digital Electronic Library Data Bases
- Access to resources encompassing >250,000 reference spectra
NMR SPECTROSCOPY
Bruker AVANCE™ 500 NMR Spectrometer
- 500 MHz proton NMR frequency
- Multinuclear Capabilities
- Multiple probes
- 5 mm inverse detection broad bank gradient probe
- 10 mm broadband-observe probe (23-203 MHz: 109Ag to 31P) with Auto Tune & Match (ATM)
- 5 mm broadband-observe gradient probe (23-203 MHz) with ATM
- 4 mm CPMAS probe (50-203 MHz)
- Features available
- Variable temperature operations (-100 to +200°C for liquids; -50 to 120° for solids)
- Multidimensional NMR capabilities
- Pulsed field gradient accessory (up to 50 G/cm)
- 60 position autosampler
- Automatic sample changer for CPMAS probe
Bruker AVANCE ™ 400 MHz NMR Spectrometer
- 400 MHz proton NMR frequency
- Multinuclear capabilities
- Multiple probes
- 10 mm broadband gradient probe (40-162 MHz) and ATM
- Variable temperature operations (-130 to +150°C)
- Features available
- Multidimensional NMR capabilities
- Pulsed field gradient accessory (up to 50 G/cm)
- 60 position autosampler
Bruker AVANCE ™ 400 MHz NMR Spectrometer
- 400 MHz proton NMR frequency
- Multinuclear capabilities
- Multiple probes
- 5 mm broadband/19F-observe gradient probe with 1H/19F decoupling and ATM
- Variable temperature operations (-80 to +130°C)
- 10 mm broadband gradient probe (40-162 MHz) and ATM
- Variable temperature operations (-130 to +150°C)
- Features available
- Multidimensional NMR capabilities
- Pulsed field gradient accessory (up to 50 G/cm)
- 60 position autosampler
OPTICAL MICROSCOPY
Nikon Optiphot-Pol Polarized Light Microscope
- reflected light
- transmitted polarized light
- multiple objectives; 5x, 10x, 20x, 40x, 100x
- 20x, 40x extra long working distance objectives
Capabilities and uses
- birefringence, refractive index
- interference figures, dispersion staining
- calibrated slide, eyepiece reticle for sizing
- photographic and video documentation capability
Olympus SZX12 Stereo Light Microscope
- 3.5x to 128x magnification
- reflected and transmitted light sources (bright field & dark field)
- digital photography / video documentation / measurement capabilities
SCANNING ELECTRON MICROSCOPY
Tescan Vega-II Scanning Electron Microscope
- Secondary electron detector
- Backscatter electron detector
- Infrared sample chamber camera
- W electron source operates from 200eV (for low kV imaging) -30keV
- Optical Range from 4x - ≥ 100,000x.
- Oxford Inca EDS system
- Turbo-molecular vacuum system for cleaner operation
Philips XL30 Environmental Scanning Electron Microscope
- Detectors
- Secondary electron detector
- Backscatter electron detector
- Gaseous secondary electron detector
- Gaseous large field detector
- LaB6 source (low kV imaging)
- Imaging in wet/gaseous environments up to 50 torr
- Peltier cooled specimen stage (-5 to 60°C)
- EDAX Phoenix / 4Pi EDS system
- Infrared sample chamber camera
X-RAY POWDER DIFFRACTION
Panalytical X'pert Pro MPD System
- transmission or reflective mode using focused or parallel beam optics
- 1800W Copper tube capable of line or point focus configurations
- Theta/2-Theta drives may be decoupled for thin film applications
- Powder analysis w/ 27 mm sample holder or glass micro-capillaries
- Small spot analysis for sample ≥ 50x50 microns
- High temperature furnace capable of applications up to 1200°C
- Computer-based JCPDS library for rapid, positive phase identifications
- Low angle analysis of crystalline films and coatings
SURFACE ANALYSIS
Dataphysics OCA-20 Contact Angle Analyzer
- Software-controlled measurement and analysis of the static and dynamic contact angles, surface free energy of solids and their components and surface and interfacial tension based on the analysis of lamella drop shapes
CAHN DCA-315 Dynamic Contact Angle Analyzer
- PC driven microbalance capable of measuring contact angle, surface tension, critical micelle concentration
- Automated surfactant doser for critical micelle concentrations
- Variable temperature capability
X-RAY FLUORESCENCE SPECTROSCOPY
Philips PW2404 Wavelength Dispersive X-Ray Fluorescence Spectrometer
- Analysis of powders, liquid, slurries
- 4 kW X-Ray Tube
- 24 Position autosampler
- 5 crystals for diffraction
- Scintillation, flow, sealed, and duplex detectors
- SemiQ software package for semi-quantitative standardless analyses
- Sensitivity from a few ppm to 100%
- Detection of elements C - U
MASS SPECTROMETRY INCLUDING LIQUID CHROMATOGRAPHY (LC/MS)
Bruker MicroFlex Mass Spectrometry
- Time of flight mass analyzer
- MALDI (matrix assisted laser desorption ionization) ion source with pulsed ion extraction
- Features available
- 20 Hz nitrogen laser
- Liner and reflectron operation mode
- PSD (post source decay) experiment
JEOL AccuTOF-D Mass Spectrometry with LC/MS capability
- Time of flight (TOF) mass analyzer with reflector
- Ionization techniques:
- DART (IonSense Direct Analysis Real Time) ion source
- Electrospray (ESI)
- Atmospheric pressure chemical ionization (APCI)
- Feature available:
- Positive/negative ion detection
- Mass range up to 10K Daltons
- Mass accuracy within 5 mmu for mass less than 1500
- Agilent 1100LC system with diode-array UV detector
- ESI interface for LC with 100-200 µl/min flow rate
- APCI interface for LC with 250 µl/min to 1 ml/min flow rate
- Direct flow injection or infusion using ESI or APCI
- Direct solid or liquid sample analysis using DART
Finnigan TSQ-7000
- Triple quadruple mass spectrometer
- Ionization techniques:
- Electrospray (ESI)
- Atmospheric pressure chemical ionization (APCI)
- Features available:
- Positive/negative diction ion mode
- Agilent 1100LC system with variable wavelength UV detector
- Collision induced dissociation (CID) experiments
- ESI interface for LC with 5-50 µl/min flow rate
- APCI interface for LC with 100 µl/min to 1 ml/min flow rate
- Direct flow injection or infusion
- Mass range up to 2500 Daltons
|
| |
|
Please click on link for information about
particular lab.
|
|
|
Contact
| Services| Capabilities
| Laboratory | Clients
Only
Laboratory
| Labs & Instruments | Virtual Tour
©2009 Ashland
® Registered Trademark, Ashland Inc.
Privacy Notice -- Terms of Use
*Responsible
Care and Responsible Care logo are Registered service marks of the American
Chemistry Council in the U.S. and of other entities in other countries.
Site
development by 1 Firm, Inc.
|
 |